EXCELL PRECISION CO., LTD.
Counting ZSME200000003
28
4-2-3 Weight Preset
The scale can store a Hi Limit unit weight value. The scale will make a warning
beep and the unit weight window will display a blinking
if the unit weight is over the Hi limit value stored.
Set the Hi Limit value for unit Weight
Œ Press
QTY PST
key whether the scale has object on the weigh pan or not.
0
3
Stable
3
Latest Preset Value
Enter a desired Hi Limit value. Use
CE
key to correct the value entered.
0
3
Stable
3
Hi Limit Value Entered
4 The unit and the decimal points for the high limit value entered are the same as the value
previously preset on the weight display.
Ž Press
UNIT W.T.
key. Use
CE
key to correct the value entered.
0
3
Stable
3
Press
QTY PST
key, the scale will return to counting mode.
0
3
.
Stable
3
Clear the Hi Limit unit weight and quantity values
To clear the Hi Limit unit weight or Quantity preset enter 0 as the value in the